Electricity is a critical resource for modern living, yet residential consumers are often unaware of their actual power consumption until a bill arrives or an appliance fails. Existing remote-monitoring solutions typically depend on graphical dashboards or mobile applications that place a heavy demand on data bandwidth, which is unreliable in regions with poor internet infrastructure. This paper presents the design, simulation and experimental evaluation of a real-time power usage alert system built around an ESP32 microcontroller, a PZEM-004T energy metering module, and a lightweight Telegram Bot interface for remote notification, complemented by a 16x2 I2C LCD, an active buzzer and an LED for local feedback that remains functional without an internet connection. A hybrid research design combining mathematical modelling, Wokwi-based simulation and physical experimentation was adopted. The firmware continuously polls the PZEM-004T over UART2, compares the instantaneous active power against a user-configurable threshold, and triggers dual local and remote alerts with a 40W hysteresis margin to prevent nuisance notifications. Bench testing against a calibrated digital multimeter over a 60-250 W load range gave a peak voltage error of 0.14%, corresponding to an overall measurement accuracy of approximately 99.2%. Telegram alerts were delivered in an average of 1285 ms across five overload trials, and the local buzzer and LED responded correctly in every test. The developed system achieved high accuracy while keeping bandwidth demand to a minimum, making it well suited to low-connectivity residential settings.